Images: Alt
Product Short Description: H2S vial (Bacteriological ) Kit is for checking Microbiological Quality of water. 1 PACK = 1 TEST
Product Description:

H2S vial (Bacteriological ) Kit use for checking microbiological quality of water. Water borne diseases like typhoid ,cholera, diarrhoea and jaundice and caused  by polluted water supply. The conventional method for testing the microbiological quality of water needs the service of  a qualified microbiologist , laboratory facilities  and take 60 - 72 hours to know the result. And further the laboratory may charge any amount per sample for the test. The new devloped screening test ,  done at field itself, dispenses with all these problems and will cost  & timing much less.

Product Application:

H2S vials test of water.
What is H2S Strip Test Kit?
RXSOL  H2S Strip Test is ready to use simple device based on hydrogen sulphide indicator bacteria for carrying out bacteriological examination of drinking water. The Hydrogen Sulphide Paper Strip Method.

The Hydrogen Sulphide Paper Strip Method developed by Manja et al. (1982) is an on site testing method for the microbial quality of drinking water and is based on the detection of hydrogen sulphide producing bacteria rather than the coliform bacteria. Human faeces contain a high concentration of sulphate reducing bacteria of up to 1010/g (Levett, 1993) and some of the enteric bacteria such as Salmonella, Proteus, Citrobacter and some strains of lebsiella,also produce hydrogen sulphide. 
Sterlized paper strip treated with media is kept in sterlized glass bottle. The water sample is filled in the bottle and kept for 24 to 48 hours at room temperature (25 to 37 C).
If bacteria are present in the sample, they produce hydrogen sulphide, which turns water sample black.
Product Dose:

Method of Testing Water :

Dry and sterile media are provided in nthe screw capped bottle which are ready for use. Fill the water to be tested up to the upper level mark of the bottle. Shake the bottle gently. After 5 minute keep the bottle at room temperature of 30 to 35°C or in the incubator at 37°C  or in curdomatic for 18 hrs. If  none of these are available the bottle can kept in the pocket while sleeping in the night.

The following change may be observed -

1. No change in colour of water in the bottle  / or Change in yellow  ting  - Water is fit for drinking

2. Water in bottle  turn black   - Water is unfit for drinking . Water may have disease causing bacteria. Hence it has to be boiled or chlorinated before drinking.

:::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::
 

Features of H2S Strip Test Kit-
 
1) Ready to use: The water sample (20 ml) from the source can be directly taken in to the pressurized H2S Strip Test bottle. Presterlized bottle contains premeasured sterile media on paper strip. There is no need of preparation and sterilization of media or sterilization of bottle. Bacteriological test of sample water (20 ml) starts at sample source.
2) Simplicity: H2S Strip test kit's bacteriological test is so simple that even a layman can perform it. For the reason it is most suited for rural & remote areas and for those who do not have infrastructure to carry out standard microbiological tests.
3) Economical: H2S Strip test kit is most economical proposition. It does not require any set up or laboratory or services of microbiologist.
4) Portability: H2S Strip Test Kit is made up of glass, light in weight, easy to carry anywhere, anytime.
5) Disposable: Destroy after use.
6) Confidence: Results are reliable, meaningful and reproducible.
7) Illustrative Direction: Simple to follow illustrative direction are given which explains the use of the test kit.
 
 


 

 
Features of H2S Strip Test Kit-
 
1) Ready to use: The water sample (20 ml) from the source can be directly taken in to the pressurized H2S Strip Test bottle. Presterlized bottle contains premeasured sterile media on paper strip. There is no need of preparation and sterilization of media or sterilization of bottle. Bacteriological test of sample water (20 ml) starts at sample source.
2) Simplicity: H2S Strip test kit's bacteriological test is so simple that even a layman can perform it. For the reason it is most suited for rural & remote areas and for those who do not have infrastructure to carry out standard microbiological tests.
3) Economical: H2S Strip test kit is most economical proposition. It does not require any set up or laboratory or services of microbiologist.
4) Portability: H2S Strip Test Kit is made up of glass, light in weight, easy to carry anywhere, anytime.
5) Disposable: Destroy after use.
6) Confidence: Results are reliable, meaningful and reproducible.
7) Illustrative Direction: Simple to follow illustrative direction are given which explains the use of the test kit.
Product Note:

Advantage of the test :

  • It is a field test , hence water sample can directly be collected from the tap.
  • No need to remove the chlorine in chlorinated water since the content of the bottle instantaneously remove it.
  • No need the messure the volume of water as the level of label marked indicated in bottle.
  • The test is simple , rapid and inexpensive.
  • The test can be done even by uneducated person in field. 
Product Technical Specification:

H2S KITS FOR WATER SAMPLE TEST. (H2SKIT FOR BACTERIOLOGICAL TEST FOR DRINKING WATER)

Remarks:

1st Treatment Method ::: Variety of disease causing organisms including bacteria, yeast, fungus, spores, and viruses growing in water. Drinking Water disinfectant easiest process is  to add  1-pound of calcium hypochlorite in granular form in to 10,000 gallons of drinking water.  And Calcium Hypochlorite is widely available for use as swimming pool chlorine tablets or white powder that is much more stable than chlorine.

2nd Tretament Method ::: Potassium permagnate for water purification. : Potassium Permagnate oxidizes dissolved iron, manganese, and hydrogen sulfide into solid particles that are filtered out of the water. And potassium permagnate is one of popular option to control iron bacteria growth in wells.  After treatment with Potassium permagnate,  The solid pricipitate particles are then filtered with a multimedia filter.
 

prod_useful_area:
Product Supply Location: