BIOCIDE for Closed Loop Chilled Water

Non-Oxidizing Biocide for Cooling Water Systems – Effective Microbial Control

Non-oxidizing biocide for cooling water systems is a specialized water-treatment chemical designed to control and reduce the growth of bacteria, fungi, algae, and other microorganisms in industrial and commercial water systems. It is commonly used in closed-loop cooling circuits, recirculating cooling towers, air washers, heat exchangers, and industrial water systems.

Microbial growth can result in biofilm formation, slime deposits, fouling, unpleasant odors, reduced heat-transfer efficiency, and microbiologically influenced corrosion (MIC). Regular treatment with a suitable non-oxidizing biocide helps maintain cleaner water systems and supports efficient cooling-system operation.


Very effective controler of BACTERIA and corrosion from closed loop chilled water system.

BIOCIDE for Closed Loop Chilled Water is a powerful microbiocide which will control a wide range of troublesome microbes in both open and closed water systems.

It is a enviromentally safe and versatile anti microbial and a powerful anti oxidant, When it dissolved in water, it disintegrates to water, oxygen and carbon dioxide. All these degradation products are non toxic. It is a very powerful oxidant, whose oxidation potential outranges that of chlorine and chlorine oxides.

Cooling Water Chemical-43

BIOCIDE for Closed Loop Chilled Water

Part No: RXSOL-40-4008-210

Very effective controler of BACTERIA and corrosion from closed loop chilled water system.

Non-Oxidizing Biocide for Cooling Water Systems – Effective Microbial Control

Non-oxidizing biocide for cooling water systems is a specialized water-treatment chemical designed to control and reduce the growth of bacteria, fungi, algae, and other microorganisms in industrial and commercial water systems. It is commonly used in closed-loop cooling circuits, recirculating cooling towers, air washers, heat exchangers, and industrial water systems.

Microbial growth can result in biofilm formation, slime deposits, fouling, unpleasant odors, reduced heat-transfer efficiency, and microbiologically influenced corrosion (MIC). Regular treatment with a suitable non-oxidizing biocide helps maintain cleaner water systems and supports efficient cooling-system operation.


Very effective controler of BACTERIA and corrosion from closed loop chilled water system.

BIOCIDE for Closed Loop Chilled Water is a powerful microbiocide which will control a wide range of troublesome microbes in both open and closed water systems.

It is a enviromentally safe and versatile anti microbial and a powerful anti oxidant, When it dissolved in water, it disintegrates to water, oxygen and carbon dioxide. All these degradation products are non toxic. It is a very powerful oxidant, whose oxidation potential outranges that of chlorine and chlorine oxides.

Application

Applications of Cooling Water Biocide

1. Closed-Loop Cooling Systems

Closed-loop cooling systems can experience microbial contamination, particularly when water quality, temperature, or system conditions support microbial growth. A suitable non-oxidizing biocide can help control bacteria and fungi and reduce biological fouling.

2. Recirculating Cooling Towers

Cooling towers continuously recirculate water, creating conditions that can support microbial growth. Biocide treatment helps control algae, bacteria, fungi, slime, and biofilm, supporting efficient heat transfer and cleaner tower operation.

3. Air Washers

Air-washing systems use circulating water and can become susceptible to microbial contamination. A properly selected biocide can help control biological growth and maintain cleaner circulating water.

4. Heat Exchangers

Microbial deposits and biofilm can accumulate on heat-transfer surfaces and reduce heat-transfer efficiency. Biocide treatment can form part of a preventive water-treatment program to control biological fouling.

5. Industrial Process Water Systems

Non-oxidizing biocides are also used in selected industrial water circuits where microbial growth can affect equipment performance, water quality, or production processes.

 

marine / Industrial circulating cooling water for both open and closed loops ( including food contact )
Milk & Dairy products processing and packaging plants.
Wineries, vineyards and breweris plant
Meat, Seafood, poultary and vegetable processing plants
Cleaning, sanitising and disinfections of UF & RO membranes
Waste water treatment ( odour control agent, disinfectant and cleaner )
Hospital & Health care facilities, veterinary clinics
Hatcheries and egg processing unit.
Dish and table ware sanitizer

Dosage

Technical Specification

Specification


Form: Liquid
Colour: Colourless
pH: 3 – 5
Specific gravity: >1.2
Solubility in water: Completely miscible
Boiling point: >100 oC
Decomposition temp: Decomposes at boiling point
MSDS

Heading1 - Varanasi Chemical

 

Product Name BIOCIDE for Closed Loop chilled water 210 Ltrs
Product code RXSOL-40-4008-210

Company Details:

RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA

Stock Point ::: Mumbai, Gandhidham, Visakhapatnam, Chennai, Kolkata, Fujairah - UAE, Barka - Oman

Phone +91 22 27815541  / 42 
Fax +91 22 2781 1318 :::AOH :0091 9821214367
Email mail @ rxmarine.com

 Heading2 - Varanasi Chemical

INGREDIENTS

Toxicity

# CAS

%

Poly [oxyethylene (dimethyliminio)

Ethylene (dimethyliminio) ethylene dichloride

 NA    31075-24-8   5-15
Magnesium Nitrate      
Benzalkonium Chloride   68424-85-1 20-25
Proprietory blend of isothiozolinone   - 1-10

 Heading3 - Varanasi Chemical

skin contact

Irritation
Eye contact  Prolonged or repeated contact may be irritating.

 

 

 

Ingestion

May result in irritation and internal damage.

Ingalation

N/A

 Heading4 - Varanasi Chemical

EYE

Flush eyes with water for 15 minutes, seek medical attention.

SKIN

Wash with soap and water

INGESTION

Drink 3-4 glasses of water or milk. DO NOT INDUCE VOMITING Get medical

attention

 Heading5 - Varanasi Chemical

Flammability

NA

Upper and lower explosion limits


N/A

Hazardous combustion products

N/A

Special procedures

N/A

Heading6 - Varanasi Chemical

Storage requirements

N/A

Special shipping information

N/A

Handling procedures and equipment

Goggles and rubber gloves.

Heading7 - Varanasi Chemical

Leaks and spills procedures

Soak up with sand or other absorbent material. Transfer into an appropriate container. Rinse residue with water

Waste disposal

According to local laws.

Heading8 - Varanasi Chemical

Eye protection

Wear goggles

Gloves

Wear rubber gloves

Ventilation

Adequate ventilation

Others measures

KEEP OUT OF REACH OF CHILDREN

Heading9 - Varanasi Chemical

Appearance

Clear to Yellowish liquid

Vapour density

NA

Solubility in water

Soluble

Vapour pressure

N/A

Boiling point

>100oC

Freezing point

<0oC

Specific gravity

1.05

pH

Acidic

Heading10 - Varanasi Chemical

 

Chemical stability

Stable

Incompatibility to other substances

NA

Reactivity

NA

Heading11 - Varanasi Chemical

 

EYE

Irritation.

SKIN

Prolonged or repeated contact may be irritating.

INGESTION

May result in irritation and internal damage

INHALATION

N/A

Heading12 - Varanasi Chemical

 N/A

Heading13 - Varanasi Chemical

 

Waste disposal

According to local laws.

Leaks and spills procedures

Soak up with sand or other absorbent material. Transfer into an appropriate container. Rinse residue with water

Heading14 - Varanasi Chemical

  N/A

Heading15 - Varanasi Chemical

 N/A

Heading16 - Varanasi Chemical

The information contained in this literature is believed to be accurate and is offered in good faith for the benefit of the customer. The company however, can not assume any liability or risk in the use of its chemical product since the conditions of use are beyond our control.

DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.