Condensers Lab Eqp
Part No: RXSOL-61-2868-001
RXSOL Sewage Test kit have been developed to meet the requirement of Sewage test
RXSOL Sewage Test kit have been developed to meet the requirement of Sewage test.Each of the tests is performed simply without the use of complicated equipment and are suitable without formal training in water testing and analysis. RXSOL Sewage Test kit are based on those recommended by the Department of the Environment and the Water Research Centre, and accord generally with the methods laid down in “Analysis of Raw, Potable and Waste Waters”.
Secondly The contamination of sea water due to raw sewage is a serious health hazard, while in coastal areas sewage can also lead to oxygen depletion and an obvious visual pollution. The RXSOL Sewage Test Kit was developed to offer offshore rigs and sea vessels the complete monitoring solution for their water systems. The kit will aid with the compliance of MARPOL Annex IV, especially for the initial/renewal inspections and spot checks for certification. RXSOL SEWAGE TEST KIT is very user friendly test kit . The using procedure of kit speaks for itself that the Kits and the results are acceptable to the Department of Environment and other authorities involved.
Application
The way a ship installation is allowed to process and dispose of sewage can vary from region to region, and because of this the operator needs to ensure high standards are always maintained.Vessels need to be compliant with regulations at all times, and with the help of RX Marine International you can ensure you operate legally, efficiently and responsibly. Our sewage test kits give you accurate information about the integrity of your system, and can give you vital early warnings about any issues which may be causing problems.
Our marine sewage treatment products are designed to provide you with the data you need in a simple and straightforward manner. Easy to operate and offering precision accuracy, they are a must-have for all operators.The tests that are included in the Sewage Effluent Test Kits are the following:
Chlorine Value
Permanganate Value
pH
Turbidity
Suspended Solids
Dosage
Usage :
Chlorine Value : Chlorine valu determine the 0-25 PPM
Permanganate Value - enables the Permanganate Value (PV) to be determined and the effluent classified as to its acceptability for discharge.
Permanganate Value Range: 0 - 30+
The RXSOL Permanganate Value test is a simplified version of the standard AO test for indicating the general quality of final effluents. The test enables the Permanganate Value (PV) to be determined and the effluent classified as to its acceptability for discharge.
pH Test Range: 4 - 8
Chemical and biological reactions at sewage works are profoundly influenced by pH. A regular check on the sewage effluent is therefore essential. A pH test will also check, for example, on the effect of acid or alkaline trade wastes in the effluent flow. The pH test is carried out using a Universal pH test tablet in conjunction with a printed colour strip.
Turbidity and Suspended Solids :
Range: 5 - 500 JTU
The Turbidity Test is designed to give a measure of the suspended solids content of the final effluent. It is also useful in following the day-to-day variation in the quality of sewage and effluent. The Palintest Turbidity Test uses a specially calibrated plastic tube. This provides the simplest possible method of performing this important test.
Temperature Range: -10 - +50 ˚C
A check should be maintained on the temperature of effluent discharges and these should always be close to ambient temperatures. A check is particularly important on industrial effluents where heated processes are involved. We provide with our test kit -10° to +50° thermometer complete . Replacement thermometers are available in the event of breakage.
Probable BO BO D, COD :
It is possible to derive an indication of the Biochemical Oxygen Demand (BOD), Chemical Oxygen Demand (COD) and Total Organic Carbon (TOC) from the result of the Permanganate Value test. This is based on the relationship between these measures of organic pollution obtained experimentally for domestic sewage and effluents.
MSDS

| Product Name | Sewage Test Kit |
| Part Number | RXSOL-62-5535-001 |
Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA
| Phone | +91 22 65113333 / 5555 / 9999 |
| Fax | +91 22 2781 1318 :::AOH :0091 9821214367 |
| 123 @ rxmarine.com | |
| Website | www.rxmarine.com |

This is combine kit
| Ingrident | CAS Number | Qty. |
| COD Test Kit | .................... | 1 Set |
| Chlorine Test kit | ..................... | 1 Set |
| pH Test Paper | ..................... | 1 Box |

| Classification | Not classified as a Dangerous Good under NZS 5433:2012. |
| Signal Word | Xi; Irritan |
| Hazard Statement | May be harmful if swallowed. Causes skin irritation.Causes eye damage. |
| Precaunory Statement | Non flamable Liquid. |
| Skin | Irritant |
| Eyes | Risk of damage to eyes. |
| Inhalation | Do not breathe vapour/spray |
| Ingestion | NA |

| Skin | Generally the product does not irritate the skin. In case of contact, immediately flush skin with plenty of water for at least 15 minutes while removing contaminated clothing and shoes. Cold water may be used.Wash clothing before reuse. Thoroughly clean shoes before reuse. |
| Eyes | Rinse opened eye for several minutes under running water. Check for and remove any contact lenses. Cold water may be used. Get medical attention. |
| Inhalation | Supply fresh air; consult doctor in case of complaints. If breathing is difficult, give oxygen. Get medical attention. |
| Ingestion | Rinse mouth with water. If swallowed, give a glass of water to drink. If vomiting occurs give further water. Seek medical advice. |

| Flash Point | Non Flammable |
| Flash Point Method | Not applicable |
| Autoignition Temperature | Unknown |
| Suitable extinguishing agents | Not combustible, however, if material is involved in a fire use: Fine water spray, normal foam, dry agent (carbon dioxide, dry chemical powder). |
| Special hazards arising from the substance or mixture | No further relevant information available |
| Advice for firefighters | Not combustible, however following evaporation of the water component of the material, the residual material can burn if ignited. On burning will emit toxic fumes. Fire fighters to wear self-contained breathing apparatus and suitableprotective clothing if risk of exposure to vapour or products of combustion. |

| Small Spillage | Always wear recommended personal protective equipment. Evacuate unprotected personnel. |
| Large Spillage |
Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust). Ensure adequate ventilation. |
| Environmental precautions | Dilute with plenty of water. Do not allow to enter sewers/ surface or ground water |

| Handling | Use of safe work practices are recommended to avoid eye or skin contact and inhalation. Observe good personal hygiene, including washing hands before eating. Provide adequate ventilation |
| Storage | Store in the closed, original container in a dry, well ventilated area. Keep container tightly closed when not in use. Protect from light, heat and contamination by organic materials (will affect product stability). Keep away from Children |
| Incompatibilities | No further relevant information available. |

| Engineering Control | Local exhaust ventilation is recommended when vapours can be released in excess of established airborne exposure limits. |
| Personal Protective Equipment | |
| Skin Protection | Disposable latex gloves and lab coat. See or follow local Standards for more information. |
| Eye Protection | For normal conditions, wear safety glasses. Where there is reasonable probability of liquid contact, wear chemical safety goggles. |
| Respiratory Protection | None generally required for adequately ventilated work situations. In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use self-contained respiratory protective device. |
| General protective and hygienic measures | Food, beverages and tobacco products should not be stored or consumed where this material is in use. Always wash hands before smoking, eating, drinking or using the toilet. Wash contaminated clothing and other protective equipment before storage or re-use. Provide eyewash fountains and safety showers in close proximity to points of potential exposure. |
| Exposure Limits | |
| Inspirable Dusr |
TWA: - ppm / 3 mg/m³ STEL: - ppm / - mg/m³ |
| Chromium (VI) compounds |
TWA: - ppm / 0.05 mg/m³ STEL: - ppm / - mg/m³ |
Gloves Suit

| Appearance | Clear./ Turbid Light orange |
| Physical State | Liquid |
| Odor | Characteristic |
| Odor Threshhold | Not Applicable |
| pH | 5-7 |
| Flash Point | Not Applicable |
| Boiling Point | 100°C |
| Freezing Point | -15°C |
| Vapor Pressure | 23 h Pa |
| Vapor Density (Air = 1.0) | Not Determine |
| Density | 1.00 |
| Flammability | Not Applicable |
| Self-igniting | Product is not selfigniting. |
| Solubility in water | 100 % Soluble |
| Danger of explosion | Product does not present an explosion hazard. |

| Stability Of Product | The product is stable. . |
| Thermal Decomposition | No decomposition if used according to specifications |
| Hazardous Decomposition | No dangerous reactions known. |
| Conditions to avoid | No further relevant information available |
| Incompatible materials | No further relevant information available. |
| Hazardous decomposition products | No dangerous decomposition products known. |
| Hazardous Polymerization | Will not occur. |

| Immediate (Acute) Effects | No LD50 data available for the product. |
| Primary irritant effect |
Ingestion: Swallowing can result in nausea, vomiting, diarrhoea, and abdominal pain. |
| Additional toxicological information | No adverse health effects expected if the product is handled in accordance with this Safety Data Sheet and the product label. Symptoms or effects that may arise if the product is mishandled and overexposure occurs |
| Chronic effects | No information available for the product. |

| Acquatic toxicity | No further relevant information available |
| Persistence and degradability | Easily biodegradable |
| Bioaccumulative potential | No further relevant information available. |
| Ecological information | Do not allow product to reach ground water, water course or sewage system |
| Other adverse effects | No further relevant information available. |

| RCRA hazardous waste | Note Applicable |
| Diaposal Condition | Refer to local government authority for disposal recommendations. Dispose of contents/container in accordance with local/regional/national/international regulations. |

| Road and Rail Transport | Not classified as a Dangerous Good under NZS 5433:2012 Transport of Dangerous Goods on Land. |
| Marine Transport | Not classified as Dangerous Goods by the criteria of the International Maritime Dangerous Goods Code (IMDG Code) for transport by sea; NON-DANGEROUS GOODS. |
| Air Transport | Not classified as Dangerous Goods by the criteria of the International Air Transport Association (IATA) Dangerous Goods Regulations for transport by air; NON-DANGEROUS GOODS. |
| Proper Shipping Name | Water Testing Kit |

| Subclass 6.1 Category E | Substances which are acutely toxic. |
| Subclass 6.3 Category A | Substances that are irritating to the skin. |
| Subclass 8.3 Category A | Substances that are corrosive to ocular tissue. |
| Hazard Statement | |
| H303 | May be harmful if swallowed. |
| H315 | Causes skin irritation. |
| H318 | Causes serious eye damage. |

|
The information above is believed to be accurate and represents the best information currently available to us. However, we make no warranty of merchantability or any other warranty, express or implied, with respect to such information, and we assume no liability resulting from its use. Users should make their own investigations to determine the suitability of the information for their particular purposes. In no event shall be liable for any claims, losses, or damages of any third party or for lost profits or any special, indirect, incidental, consequential or exemplary damages, howsoever arising, even if Rx Marine International has been advised of the possibility of such damages. |