Skip to main content
Drag

Corrosion Inhibitor for Multi Metal Cooling Water

RXSOL Corrosion Inhibitor for Multi Metal Cooling Water

 

Product Code: RXSOL-40-4011-020
Application: Treatment of Cooling and Retort Water

PRODUCT DESCRIPTION AND APPLICATION

 

RXSOL Corrosion Inhibitor for Multi Metal Cooling Water is a specially formulated corrosion inhibitor blend designed to protect multiple metals commonly found in closed recirculating cooling and retort water systems.

RXSOL-40-4011-020 is easy to apply and control. Its built-in pH buffering system helps maintain the circulating water within an optimum pH range, thereby reducing corrosion and providing effective protection to system metallurgy.

The product provides corrosion protection for systems containing carbon steel, copper, brass and other compatible metals and alloys, making it particularly suitable for multi-metal closed cooling circuits.

An indicating dye incorporated into the formulation assists with visual identification of treated water and can help in the detection of system leakage.

RXSOL-40-4011-020 is suitable for use with uninhibited antifreeze solutions and is formulated to be compatible with commonly used gaskets, pump seals and other non-metallic components when used at the recommended concentration.

Corrosion Inhibitor Additives for Water system ::: Alkaline Corrosion Inhibitor blend for multi-metal protection in closed-loop and chilled cooling water CLOSED circulating system.
This is a Highly effective INHIBITOR for closed loop , line chilled water with unique dual control of corrosion and scale from system.

This closed water treatment chemicals are  designed to treat hot and chilled water systems. The product contains a combination of molybdate, borate, and silicate formulated to minimize corrosion and deposition. The product comes in a clear and also a variant pink appearance form.
 

RXSOL-40-4011-020 is a superior multifunctional, molybdate-based chemical treatment used for the control of corrosion in closed cooling systems and chilled water systems. RXSOL-40-4011-020 is a liquid product containing a combination of ferrous and non-ferrous corrosion inhibitors, a non-carbonate buffer, scale inhibitors, dispersants and a leak detection dye.

 

 


 

Corrosion Inhibitor-44

Corrosion Inhibitor for Multi Metal Cooling Water

Part No: RXSOL-40-4011-020

Corrosion Inhibitor for Multi Metal Cooling Water is a specially formulated corrosion inhibitor blend designed to protect multiple metals commonly found in closed recirculating cooling and retort water systems.

RXSOL Corrosion Inhibitor for Multi Metal Cooling Water

 

Product Code: RXSOL-40-4011-020
Application: Treatment of Cooling and Retort Water

PRODUCT DESCRIPTION AND APPLICATION

 

RXSOL Corrosion Inhibitor for Multi Metal Cooling Water is a specially formulated corrosion inhibitor blend designed to protect multiple metals commonly found in closed recirculating cooling and retort water systems.

RXSOL-40-4011-020 is easy to apply and control. Its built-in pH buffering system helps maintain the circulating water within an optimum pH range, thereby reducing corrosion and providing effective protection to system metallurgy.

The product provides corrosion protection for systems containing carbon steel, copper, brass and other compatible metals and alloys, making it particularly suitable for multi-metal closed cooling circuits.

An indicating dye incorporated into the formulation assists with visual identification of treated water and can help in the detection of system leakage.

RXSOL-40-4011-020 is suitable for use with uninhibited antifreeze solutions and is formulated to be compatible with commonly used gaskets, pump seals and other non-metallic components when used at the recommended concentration.

Corrosion Inhibitor Additives for Water system ::: Alkaline Corrosion Inhibitor blend for multi-metal protection in closed-loop and chilled cooling water CLOSED circulating system.
This is a Highly effective INHIBITOR for closed loop , line chilled water with unique dual control of corrosion and scale from system.

This closed water treatment chemicals are  designed to treat hot and chilled water systems. The product contains a combination of molybdate, borate, and silicate formulated to minimize corrosion and deposition. The product comes in a clear and also a variant pink appearance form.
 

RXSOL-40-4011-020 is a superior multifunctional, molybdate-based chemical treatment used for the control of corrosion in closed cooling systems and chilled water systems. RXSOL-40-4011-020 is a liquid product containing a combination of ferrous and non-ferrous corrosion inhibitors, a non-carbonate buffer, scale inhibitors, dispersants and a leak detection dye.

 

 


 

Application

Applications

RXSOL-40-4011-020 is recommended for:

 

  • Closed recirculating cooling-water systems
  • Retort cooling-water systems
  • Engine and machinery cooling circuits
  • Chilled-water systems
  • Closed-loop industrial cooling systems
  • Multi-metal cooling circuits
  • Systems containing glycol-based uninhibited antifreeze
  • Industrial equipment requiring long-term corrosion protection

Cooling water treatment specified corrosion inhibitior for multi-metal containng cooling systems to operate at high or low temperatures.

Alkaline Corrosion Inhibitor blend for multi-metal protection in closed-loop and chilled cooling water CLOSED circulating system

Dosage

For systems containing no aluminium, RXSOL-40-4011-020 should be dosed at 0.5 to 1% (5 L–10 L/ 1000 L) in order to give a reserve of 50 ppm of sodium molybdate. For systems containing aluminium, the dosage of 1–1.5% should be added in order to maintain a minimum reserve of 100 ppm of sodium molybdate. In certain circumstances it may be necessary to adjust the pH separately by the addition of pH CONDITIONER - your Consultant will advise. In systems requiring significant passivation/higher initial dosages may be required to yield the required inhibitor residual.

Normal treated water control limits

pH 7.0 - 9.0 (Without Aluminium)

pH 7.0 - 8.0 (With Aluminium)

For systems containing aluminium it is important to maintain the system water pH in the range 7.0 - 8.0. Occasionally depending on the water characteristics and system treatment history the pH may rise above pH 8.0 which means that the risk of aluminium corrosion is increased - if this happens then high pH can be reduced by adding an appropriate quantity of pH Conditioner.

Technical Specification

Multi-metal corrosion protection • Built-in pH buffering • Suitable for closed recirculating systems • Helps protect steel and copper alloys • Indicating dye for easier leak identification • Compatible with uninhibited antifreeze • Suitable for cooling and retort water treatment

MSDS

Heading1 - Varanasi Chemical

Product Name RXSOL-40-4011-020
Product Type Corrosion Inhibitor Multifunctional closed/chilled systems 

Company Details:

RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA

Stock Point : Mumbai, Kandla, Kolkata, Chennai, Visakhpatnam, Fujairah, Muscat, Nairobi

Phone +91 22 65113333 / 5555 / 9999 / 27611360
Fax +91 22 2781 1318 :::AOH :0091 9821214367
Email mail @ rxmarine.com

Heading2 - Varanasi Chemical

 Substances which give the product

HYDROXYPHOSPHONIC ACID 

 23783-26-8

01-05

SODIUM HYDROXIDE

1310-58-3

01-04

TOLUTRIAZOLE 29385-43-1 0.5-01
SODIUM Molybdate as Corrosion Inhibitor 7631-95-0 10-20
SODIUM BORATE as pH Buffer 1303-96-4 0.1-0.5
Silicate as a Aluminium Corrosion Inhibitor 1344-09-8 09-10
Azole as a Copper Corrosion Inhibitor 109-97-7 01-02
Properitory Blend of Polymer as a Dispersency Stabilization --- 10-20

Heading3 - Varanasi Chemical

Inhalation

 NOT APPLICABLE

Eye Contact

MAY CAUSE IRRITATION

Skin Contact

 MAY CAUSE IRRITATION

Ingestion

MAY CAUSE IRRITATION.

Heading4 - Varanasi Chemical

Inhalation

NOT APPLICABLE

Eye contact

WASH IMMEDIATELY WITH PLENTY OF WATER

Skin Contact

 REMOVE IMMEDIATELY CONTAMINATED CLOTHING AND WASH SKIN

Ingestion

DRINK PLENTY OF WATER

Information to Doctor: NEAR NEUTRAL SOLUTION CONTAINING ORGANIC PHOSPHONATES

Heading5 - Varanasi Chemical

Fire and Explosion Hazards

WATER BASED PRODUCT WITH NO SPECIAL HAZARDS

Precautions: None
Extinguishing media:  NO SPECIAL MEDIA REQUIRED
Not suitable extinguishing media: NONE

 

Heading6 - Varanasi Chemical

ADSORB BY INERT MATERIAL.
FLUSH SPILL AREA WITH PLENTY OF WATER. 
THE ALKALINE HAZARD OF THE PRODUCT IS REMOVED BY DILUTION WITH WATER

Heading7 - Varanasi Chemical

Handling

WEAR GLOVES, EYE PROTECTION AND OVERALLS.

Storage

STORES INDOORS AND PREVENT FROM FREEZING.

Heading8 - Varanasi Chemical

Exposure Control

AVOID EYE AND SKIN CONTACT

Personal protection

WEAR GLOVES, GOGGLES AND OVERALLS WHEN HANDLING THE MATERIAL.

Heading9 - Varanasi Chemical

Appearance

Clear Liquid

Boiling point

100 C

C Density [kg/m3]

1.05-1.1

Flashpoint TCC

NONE Vapour pressure [mm Hg]

Pour point 

NONE Vapour density [a ir=1]:

Auto-ignition temp  NONE Soluble in organic solvent: NONE
Expl.omr. [vol%] Solubility in water [w-%]: 100%
pH concentrate: 11.5 - 12.0 pH 
Rel. evaporation Rate. N/A
Ether = 1 Butylacetate = 10 0
Freezing Point >-20 Degree C

Heading10 - Varanasi Chemical

 

Stability

THE PRODUCT IS STABLE AND HAS A SHELF-LIFE OF 2 YEARS

Avoid blending with

ACIDS

Dangerous products of degradation NONE
Dangerous products of combustion NONE

 

Heading11 - Varanasi Chemical

Analysis data

LD [RAT] >50 00 mg/kg [CALCULATED] 50 CONSIDERED TO BE NON-TOXI


Heading12 - Varanasi Chemical

Analysis data:

LD RAINBOW TROUT > 500 mg/l [CALCULATED] 50 CONSIDERED TO BE OF NO DANGER TO THE ENVIRONMENT

 Remarks:

Heading13 - Varanasi Chemical

Recommendations:

ALKALINE PRODUCT WHICH IN USE IS DILUTED DOWN CONSIDERABLY AND ALLOWED TO ENTER THE ENVIRONMENT.

Heading14 - Varanasi Chemical

This substance is not dangerous under current provisions of the Code of International Carriage of  Dangerous  Goods by  Road  (ADR)  and  by  Rail  (RID),  of  the  International  Maritime  Dangerous  Goods  Code  (IMDG),  and  of  the International Air Transport Association (IATA) regulations.

Heading15 - Varanasi Chemical

 

Chemical health hazard:

HARMFUL/IRRITANT

Chemical to the environment

.

Infla mmable product  
Explosive product  
Labelling category [-s]: HARMFUL/IRRITANT
 Symbol [-er]:  Xn, Xi
R-phrase [-s]: R21-Harmful in contact with skin, R36-Irritating to eyes, R38-Irritating to skin
 S-phrase [-s]: S61-Avoid release to the environment, S45-In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible).

Heading16 - Varanasi Chemical

NO CARCINOGENIC PROPERTIES HAS BEEN FOUND WITH ANY INGREDIENTS.

NO EVIDENCE OF MUTAGENIC EFFECTS

EXPOSURE LIMITS NOT ASSIGNED

Legal Disclaimre:-

The above information is based on the present state of our knowledge of the product at the time of publication. It is given in good faith, No warranty is implied with respect to the quality or the specif ication of the product. The user must satisfy himself that the product is entirely suitable for his purpose.

DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.