Skip to main content
Drag

Lodine

Lithium Silicate Based Concrete Stone Densifier manufacturer, supplier and Exporter.  RXSOL densifier chemically fills in pores and capillaries in concrete for a smoother surface and to increase surface density to achieve a higher gloss when polishing.

It can be use on existing aggregate and concrete of any age. 

Lab Chemical-60

Lodine

Part No: RXSOL-60-6155-001

RXSOL densifier chemically fills in pores and capillaries in concrete for a smoother surface and to increase surface density

Lithium Silicate Based Concrete Stone Densifier manufacturer, supplier and Exporter.  RXSOL densifier chemically fills in pores and capillaries in concrete for a smoother surface and to increase surface density to achieve a higher gloss when polishing.

It can be use on existing aggregate and concrete of any age. 
Application

Concrete and Stone Densifier is used on polished and non-polished concrete to reduce dusting and wear. On polished concrete surfaces, densifiers help concrete take a higher polish and make the surface less permeable to liquids so less sealer is needed.

Densifiers are used on nonpolished concrete mainly to reduce dusting and improve stain resistance. Using RXSOL Concrete and Stone Densifier will allow a higher gloss when followed by polishing or sealing. It can be use on marble floors for the same purpose.  

Dosage
Maintain Temperature of floor in between 10 degrees C and below 37 degrees C. Also for out side application it will not rain for several hours. CLEAN surface completely mainly make OIL grease, wax free, If possible before one days or Air movers can be used to shorten drying time. . Check the absorbency of each slab before proceeding. Spray section with water to determine how absorbent the concrete is and if absorbency is consistent. This will also help you determine the coverage that should be expected. 
 
 
 
Apply RXSOL  Densifier undiluted with lowpressure sprayer. Apply enough product to wet the surface without forming puddles. Spread evenly with soft synthetic brush. After application surface should take minimum 5 to 10 minutes to dry if dryness occurs immediately or in 2 - 3 minutes then apply densifier again. Allow treated surfaces to dry before any additional procedures are initiated. After drying, remove any powdered residue using a stiff brush before continuing. At this point the floor can be polished and/or sealed. Polishing time will be reduced and the surface will absorb less sealer.. Adjust procedures and/ or applications appropriately.  
MSDS

Heading1 - Varanasi Chemical

Product Name

RXSOL COCRETE & STONE DENSIFIER

Product Type RXSOL-41-8609-025


Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA

Stock Point : Mumbai, Kandla, Kolkata, Chennai, Vizag, Fujairah, Muscat, Kenya, Canada

Phone +91 22 65113333/ 5555 / 9999 / 27611360 / 27815540
Fax +91 22 2781 1318 :::AOH :0091 9322594669
Email mail @ rxmarine.com


Heading2 - Varanasi Chemical

HAZARDOUS INGREDIENTS:                            TLV            OSHA PEL

Silica, Amorphous (CAS 112926-00-8)                 N/E            80 mg/M3

Lithium Hydroxide (CAS # 1310-66-3)                  N/E             N/E

Proprietary Blend of Silicates, stabilizers, etc       N/E             N/E

Heading3 - Varanasi Chemical

Permissible exposure limit: None established for this product.

OSHA exposure limit: None established for this product.

Primary routes of entry: Ingestion, Inhalation, eye contact.

Effects of overexposure:

Ingestion: No Known Effects, consult a physician

Inhalation: May cause irritation of upper respiratory tract.

Eye Contact: May cause irritation.

This Product does not contain any substance listed as a carcinogen by NTP, IARC, or OSHA.

Heading4 - Varanasi Chemical

INGESTION: Not expected to be toxic.  Never give an unconscious person anything to ingest. If swallowed, immediately give two glasses of water, Seek Medical
attention if ill effects develop.

INHALATION: May cause irritation. Remove to fresh air and provide oxygen. If not breathing, give artificial respiration. Seek medical attention if irritation persists.

EYE CONTACT: In case of contact, f lush with plenty of water for at least 15 minutes. Seek medical attention if irritation persists.

SKIN CONTACT: May cause irritation. Wash affected area with soap and water. Remove contaminated clothing and shoes. Seek medical attention if irritation persists.

Heading5 - Varanasi Chemical

Flash Point: Will not flash Unusual fire and explosion

hazards: None

LEL: Not applicable

Special fire fighting procedures: None

UEL: Not applicable

Flammability class: Not applicable

Extinguishing media: Not applicable

Special Fire Fighting Procedures: None

Heading6 - Varanasi Chemical

Steps to be taken in case material is released or spilled:

Spill - Absorb with an inert material and place in an appropriate waste disposal container.

Waste Disposal Method: Sanitary landfill or sewer. Observe all environmental regulations, Federal, State, and Local regulations.

THIS PRODUCT WHEN SPILLED OR DISPOSED OF IS A NON-HAZARDOUS WASTE AS DEFINED IN RCRA REGULATION (40CFR 261).

Heading7 - Varanasi Chemical

General Handling:

Avoid breathing vapor, aerosol and mist.

Do not swallow.

Keep container closed.

Use with adequate ventilation.

Wash thoroughly after handling

Ventilation:

General mechanical room ventilation is expected to be satisfactory.. Local ventilation is needed in the presence of airborne mists.

Storage:

Product may freeze if stored below 32ºF. Product damage will occur if frozen.

 

Heading8 - Varanasi Chemical

Ventilation: Use adequate ventilation to keep airborne concentrations below the exposure standard.

Respiratory Protection: Use respirator in heavy mist locations.

Other Personal Protection: Use as desired.

Heading9 - Varanasi Chemical

Boiling Point 212º F     
Freeze Point 32ºF
Odor Mild to Odourless
Appearance Colourless to Milky Liquid
Vapor Density Unavailable
S.G. >2
V.O.C. None     
Solubility Infinite 
pH Alkaline

Heading10 - Varanasi Chemical

Stability: Stable

Incompatibility: Acidic, Cationic, and salt materials may gel the product.

Conditions to avoid: Do not mix with other material unless advised by supplier. Freezing conditions will damage product.

Hazardous decomposition products: None.

Heading11 - Varanasi Chemical

Not Established

Heading12 - Varanasi Chemical

Not Established

 Heading13 - Varanasi Chemical

Do not dispose of on the land, in surface waters, or in storm drains. Small spills and waste may be reused or flushed into a waste treatment sewer where local regulations permit. Larger quantities should be collected for reuse or consigned to a licensed hazardous waste hauler for disposal in accordance with federal, state and local regulations. All disposal must be in accordance with all federal, state and local regulations.