ProShield PC55 RO Biocide

RO Chemicals

ProShield PC55 RO Biocide

Part No RXSOL-33-8936-009

Antimicrobial used for reverse osmosis water treatment to Eliminate most microbial growth Stable, broad spectrum

Overview

Isothiazolinone based ProShield PC55 RO Biocide bactericide an antimicrobial and preservative used in a wide variety of applications, such as bactericide for reverse osmosis water treatment.

Non-oxidizing antimicrobial formulation developed for microbial control in reverse osmosis (RO) water treatment systems. It is based on glutaraldehyde, a broad-spectrum biocidal active ingredient effective against bacteria, fungi, algae and other microorganisms.

The product helps control microbial contamination, biofilm formation and biological fouling in RO pretreatment and compatible membrane systems. It is suitable for use in industrial water treatment applications where microbial growth can reduce membrane performance, increase differential pressure and affect permeate production.

 

The formulation is intended for controlled biocide treatment, system sanitization and microbial growth management, subject to membrane-material compatibility and manufacturer recommendations.

Application

For Shut Down longer than as 24 hrs, Biological growth in the RO system should be controlled. This requires the introduction of a chemical to kill bacteria and prevent growth. Any Preservation chemical would then have to be rinsed out from the system when it is restarted.

Dosage
Flow Rate during flushing should be based on the recommended cleaning instruction flow rates. This is  normally 30-40 gpm ( 6.8 to 9.1 m3/ Hr ) per pressure vessel.
 
Flushing time should be long enough for the conductivity out to equal the conductivity in. Typically 15 - 20 minutes.
 
If the permeate flush is unavailable, feed water can be  used by allowing low pressure water to replace the water within the system by delaying the inlet valve closing. Scale inhibitor should be turned off during the permeate flush.
 
if the temperature in the RO Membrane system more then 115 degree fahrenheit, flush water should be continiously passed through the system to prevent memebrane degradation.
Technical specification

Appearance Light yellow liquid
Active Ingredient 14%
Viscosity 16 cps @ 25°C
pH 2.0-4.0
Specific Gravity (g/ml) at 20°C

1.27-1.33

5-Chloro-2-Methyl-4-Isothiazoline-one

10.1 - 11.3

Magnesium (%) 4.2 - 5.5
2-Methyl-4-Isothiazoline-3-one 3.0 - 4.1

Safety data sheet (MSDS)

The MSDS for ProShield PC55 RO Biocide is sent by email. Fill in a short form and confirm your email address with a one-time code, and our team will send you the data sheet.

Request MSDS